Practical Solutions to Machinery and Maintenance Vibration ProblemsChapter 8, Vibration in BearingsSection 8, Further Considerations for Bearing Defect Vibration Amplitude and Frequency SymptomsAs vibration amplitudes due to bearing problems are often relatively
small when compared to other vibration sources, "threshold-type"
alarms that measure "overall" vibration do not usually give
adequate warning for impending bearing failure. Instead, "power
band-type" alarms, which measure "root mean square" (rms)
values, are most often more appropriate as they give a better idea of
"vibration defect energy."